Muffle installation provides for temperature uniformity in chamber ±
3°C.
-
Shorter transfer times from furnace chamber to quench tank (drives with 2 speeds)
-
High capacity circulation fan in conjunction with ceramic "muffle" system assures high temperature uniformity and optimal gas flow to the charge. Direct radiation of the heating elements on to the charge is avoided.
-
No driving elements in the furnace chamber.
-
Vestibule
offers rapid cooling system.
-
Available
in single and multiple chamber design.
-
All motor driven components offer
secondary "manual" actuation in the event of power outage.
-
Quench oil cooled via secondary
heat exchanger and fed to outer wall chamber of vestibule. Provides
for additional cooling capacity within the vestibule. Gas circulation
with guiding baffle also positively effects cooling rate in vestibule.
-
Quench oil circulation
adjustable/programmable for variable process requirements. Better
control on circulation/temperature rates in the quench oil, hence
better hardening effects.
-
Modular Construction, available in
9 different sizes. Shorter installation times.
-
Stand alone IQ system or can be integrated into a complete Heat Treatment plant with supporting AHTS systems including Flexiclean® washer, Tempering Furnace, etc.
-
Safety/Automation Benefits:
-
Low Temperature shut-off. No explosive gasses conveyed to system at temperatures less
than 750°C /
1382°F.
-
Automatic Nitrogen Purging unit.
(in the event of a disturbance in process/enrichment gas)
-
Flame
curtain in vestibule lock. Assures no Oxygen penetration into the
furnace.
-
Supporting
Sales Video Available. (See "Promotional
Items" section)